2114 3 10 all combustible mantels and similar trim shall be kept at least 6 inches from fireplace opening.
Building code gas fireplace surround.
2114 3 masonry built fireplaces 4114 3 10 all combustible mantels and similar trim shall be kept at least 6 inches from the fireplace opening.
For a fireplace with a larger opening of more than 6 square feet the icc requires a hearth that extends 20 inches or more in front and 12 inches or more along the sides.
Combustible materials and trim must be at least 6 inches from the firebox opening.
National standard building code information.
Parts of the mantel assembly located along the sides of the fireplace opening which project more than 1 1 2 inches 38mm from the face of the fireplace shall have additional clearance equal to the projection extension beyond 1 1 2 inches.
Circulating air ducts used with steel fireplace units shall be constructed of metal or masonry.
You ll want to familiarize yourself with your local building code for fireplaces.
A mantel must be at least 6 inches from the fireplace opening.
Local building codes take precedence over national and international codes but it s best if your fireplace meets or exceeds these standards.
The hearth design must be.
These are usually based on the international building code standards along with standards set by the national fire code.
The firebox lining shall be encased with solid masonry to provide a total thickness at the back and sides of not less than 8 inches 203 mm of which not less than 4 inches 102 mm shall be of solid masonry or concrete.